Titan Technical Specifications/ Temperature Rise Chart

Titan Technical Specifications/ Temperature Rise Chart

MODEL MAX FLOW KW/HR VOLTS AMPS 1.0gpm 1.5gpm 2.0gpm 2.5gpm 3.0gpm 3.5gpm 4.0gpm 4.5gpm 5.0gpm
LASER
2.8 GPM
8.5
220
32
69 deg
49 deg
34 deg
28 deg
N/A
N/A
N/A
N/A
N/A
N-10
1.5 GPM
3.2
110
29
24 deg
16 deg
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N-42
2.0 GPM
4.2
220
19
33 deg
22 deg
17 deg
N/A
N/A
N/A
N/A
N/A
N/A
N-64
2.5 GPM
6.5
220
29
51 deg
35 deg
26 deg
21 deg
N/A
N/A
N/A
N/A
N/A
N-75
2.8 GPM
7.5
220
34
60 deg
40 deg
30 deg
24 deg
N/A
N/A
N/A
N/A
N/A
N-85
3.0 GPM
8.5
220
38
69 deg
46 deg
34 deg
28 deg
23 deg
N/A
N/A
N/A
N/A
N-100
3.5 GPM
10.8
220
49
87 deg
58 deg
44 deg
35 deg
29 deg
25 deg
N/A
N/A
N/A
N-120
4.0 GPM
11.8
220
54
95 deg
64 deg
48 deg
38 deg
32 deg
28 deg
24 deg
N/A
N/A
N-160
4.0 GPM
16
220
66
109 deg
73 deg
55 deg
44 deg
36 deg
31 deg
27 deg
N/A
N/A
N-180
5.0 GPM
18
220
75
122 deg
81 deg
61 deg
49 deg
41 deg
35 deg
31 deg
27 deg
25 deg
N-210
5.0 GPM
21
220
88
143 deg
95 deg
71 deg
57 deg
48 deg
41 deg
38 deg
32 deg
29 deg
N-270
5.5 GPM
27
220
112
190 deg
128 deg
96 deg
76 deg
64 deg
56 deg
48 deg
45 deg
36 deg


Reading the temperature rise chart:

Let’s say you are interested in knowing the temperature your new Titan N120 water heater will provide you when the volume of water you are using is 1.0 gpm.

Look for the desired model (N120 in this example) in the first column. Then, move to the right until you hit the column headed with 1.0 gpm. In this case, we find that the temperature rise of the Titan N120 tankless water heater at 1.0 gpm is 95 deg F. This means that this water heater is capable of raising the incoming water by 95 deg F. There are, however, factors that make those numbers vary. Click on Factors affecting the output water temperature for more details.


NOTE: FOLLOWING MODELS NEED A 200AMP SERVICE
N-180 Double installation, two wires coming out of unit and it takes 2x40 amp breakers and 2x8awg wires
N-210 Double installation, two wires coming out of unit and it takes 2x50 amp breakers and 2x6awg wires
N-270 Double installation, two wires coming out of unit and it takes 2x60 amp breakers and 2x6awg wires